Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Int J Prosthodont ; 37(7): 63-70, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-38489222

RESUMO

PURPOSE: Low-cost resin 3D printers have been used to produce affordable interim single crowns in public and private dental practices. The purpose of this study was to assess the impact of different computer-aided design (CAD) software programs on 3D trueness, microscopic marginal and internal gaps, time to design, and interproximal contacts of low-cost 3D-printed single crowns. MATERIALS AND METHODS: This in vitro study was performed on a total of 90 standardized resin-prepared teeth adapted to a dental manikin. For comparison among CAD software programs, 45 tooth preparations received 3D-printed crowns designed with one of three CAD software programs by an experienced technician and identified as groups TRIOS (n = 15), EXOCAD (n = 15), and ZZ (Zirkonzahn; n = 15). To assess interoperator reproducibility, 15 additional crowns were designed by a dental clinician (group ZZ-DENT) and 15 by a dental prosthetic technician (group ZZ-PROS), both with basic 1-week CAD/CAM training. Finally, as a control group, 15 crowns were milled using a high-end five-axis milling device (group ZZ-CONTROL). Statistically significant differences for 3D trueness, microscopic gaps, time to design, and interproximal contacts among groups were assessed with the Kruskal-Wallis test. RESULTS: No statistically significant differences in 3D trueness or marginal or internal gaps were found, either among different software programs or CAD operators (P > .05). However, Group TRIOS took significantly longer to design than EXOCAD and ZZ groups (P = .001). Less-experienced operators were significantly outperformed in time and interproximal contacts (P = .001) by the CAD technician using the same software program. Finally, control milled crowns (ZZ-CONTROL) significantly outperformed the respective 3D-printed copies (ZZ) in all assessed variables (P < .001). CONCLUSIONS: Different CAD software programs may affect the time required to design, but they do not significantly affect clinical outcomes of low-cost 3D-printed resin crowns if designed by an experienced CAD technician.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Reprodutibilidade dos Testes , Coroas , Desenho Assistido por Computador , Software , Impressão Tridimensional , Porcelana Dentária
2.
Int J Prosthodont ; 35(5): 684-689, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36511793

RESUMO

PURPOSE: To compare the accuracy of dentists with different levels of expertise in computer-aided design (CAD) and prosthodontics to digitally design single crowns. MATERIAL AND METHODS: This in vitro study was conducted on 12 prepared teeth in 2 reference dental study models. The models were scanned using an intraoral scanner. Four dentists with different levels of clinical and CAD expertise (PROS: clinicians experienced in prosthodontics [n = 2]; CAD: experts in CAD [n = 2]) performed digital waxing on all prepared teeth using the same CAD software program. The resulting digital crown designs were compared to STL files of the original teeth to assess 3D deviations. The total cervical, distal, mesial, and occlusal surface deviations of the crowns from both groups were compared using paired t and Wilcoxon signed-rank tests (α = .05). RESULTS: The total median 3D deviation was 0.10 mm (range: 0.03 to 0.61 mm) for the PROS group and 0.14 mm (range: 0.07 to 0.58 mm) for the CAD group. The PROS group presented significantly smaller total 3D (P = .021) and cervical margin (P = .001) deviations. There were no significant differences between groups on the distal, mesial, or occlusal surfaces (P > .05). The CAD group performed digital waxing significantly faster (P = .001). CONCLUSION: Within the limitations of this study, the present findings suggest that clinical experience has a higher impact on the accuracy of digital wax patterns of single crowns than CAD experience.


Assuntos
Cerâmica , Planejamento de Prótese Dentária , Planejamento de Prótese Dentária/métodos , Coroas , Desenho Assistido por Computador , Software
3.
Int J Comput Dent ; 25(4): 361-368, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36426840

RESUMO

AIM: There is controversy in the literature regarding clinical outcomes of CAD/CAM laminate veneers. The aim of the present study was to assess the impact of different levels of CAD expertise and different software programs on the reliability and reproducibility of digital wax patterns of laminate veneers and single crowns. MATERIALS AND METHODS: The present preliminary in vitro study was performed on 10 prepared maxillary central incisors available in dental study models. Of the total, five central incisors were prepared with shoulder finish lines for single crowns, whereas the other five underwent incisal shoulder preparation for laminate veneers. The models were scanned using an intraoral scanner. Four dentists (group DENT) and four CAD dental technicians (group CAD) with expertise in different software programs performed digital diagnostic waxing on all prepared teeth. The resulting digital wax patterns (n = 80) were exported as standard tessellation language (STL) files and superimposed on gold standard digital wax patterns (obtained from the original shape of the teeth before preparations). 3D mesh deviations at the cervical margins as well as distal, mesial, and incisal/palatal surfaces between each STL and the gold standard digital wax patterns were calculated in millimeters using a CAD software program. The mean time required by each operator to perform digital waxing was also recorded. Paired comparisons between groups DENT and CAD as well as between nondental and dental software programs were performed for the crowns and laminate veneers using the Wilcoxon signed-rank and paired t tests (α = 0.05). RESULTS: For group DENT, median deviations for single crowns were 0.15 mm (range: 0.08 to 1.05 mm) and for laminate veneers they were 0.15 mm (range: 0.08 to 0.76 mm). For group CAD, median deviations for single crowns were 0.16 mm (range: 0.09 to 0.73 mm) and for laminate veneers they were 0.10 mm (range: 0.06 to 0.53 mm). The Wilcoxon signed-rank test revealed a statistically significant difference between groups DENT and CAD (P = 0.041) and between the software programs (P = 0.029) for laminate veneers, but not for single crowns (P > 0.05). Furthermore, mean times required for group CAD and for dental software programs were significantly shorter than those for group DENT (P = 0.001) and for nondental software programs (P = 0.001), respectively. CONCLUSION: Within the limitations of the present study, the findings suggest that CAD expertise and the software program significantly affect digital wax patterns for laminate veneers, but not for single crowns. (Int J Comput Dent 2022;25(4):361-0; doi: 10.3290/j.ijcd.b3555819).


Assuntos
Planejamento de Prótese Dentária , Facetas Dentárias , Humanos , Reprodutibilidade dos Testes , Planejamento de Prótese Dentária/métodos , Porcelana Dentária , Desenho Assistido por Computador , Coroas
4.
J Prosthet Dent ; 2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35431028

RESUMO

Digital workflows have been used to enhance the predictability of oral rehabilitations. However, techniques to digitally design and manufacture esthetic space maintainers by following a prosthetically driven treatment plan for young patients are lacking. This technique report describes a full digital workflow to produce computer-aided design and computer-aided manufacturing (CAD-CAM) esthetic space maintainers by using intraoral scans, a dental CAD software program, and a milling machine. CAD-CAM space maintainers can be provided for young patients with satisfactory patient compliance and with minimal chairside adjustment.

5.
J Prosthet Dent ; 127(1): 128-133, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33198990

RESUMO

STATEMENT OF PROBLEM: The digital waxing of single crowns can be affected by the quality of intraoral scans and use of computer-aided design (CAD) software programs. However, clinical outcomes of the resulting crowns are also affected by computer-aided manufacturing (CAM) methodologies. Studies on the effect of different levels of expertise on digital waxing are lacking. PURPOSE: The purpose of this in vitro study was to assess the impact of different levels of expertise on the reliability and reproducibility of margin outlining during digital waxing. MATERIAL AND METHODS: Thirty analogs of implant stock abutments (Ø4.8×4 mm) were embedded into resin blocks. To simulate different clinical situations, abutments were divided into 3 groups: 10 abutments (group GOS) received artificial gingiva and were scanned with an open system intraoral scanner, while 10 abutments with (group GIS) and 10 abutments without artificial gingiva (group IS) were scanned with an intraoral scanner within an integrated CAD-CAM system. All resulting standard tessellation language (STL) files were used by 2 different observers (an experienced CAD professional and a clinician with basic CAD knowledge) to digitally design a left mandibular central incisor in the same software program. All resulting digital crown designs were exported to STL files to assess crown margin accuracy at the coupling interface by superimposition with the control STL file of the scan body designed for the same abutment by the manufacturer. For this purpose, a CAD software program was used to automatically calculate median, minimum, and maximum deviations of margins in millimeters. Statistically significant pairwise differences among groups and between observers were assessed with the Wilcoxon signed-rank test (α=.05). RESULTS: For the CAD professional, median deviations between designed crown STL files and the control STL of the scan body were 0.08 mm (range: 0.04 to 0.15) for group GOS; 0.10 mm (range: 0.06 to 0.18) for group GIS; and 0.05 mm (range: 0.03 to 0.08) for group IS. For the clinician, median deviations were 0.08 mm (range: 0.04 to 0.12) for group GOS; 0.11 mm (range: 0.07 to 0.17) for group GIS; and 0.05 mm (range: 0.04 to 0.11) for group IS. There were no significant differences between observers (P>.05). However, statistically significant differences were found between group IS and the other 2 groups (P=.001) but not between groups GOS and GIS (P>.05). CONCLUSIONS: The present findings suggest that a digital wax pattern made with a dental CAD software program is not affected by varying levels of expertise but might be affected by subgingival margins.


Assuntos
Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Gengiva , Reprodutibilidade dos Testes
6.
Imaging Sci Dent ; 51(4): 413-419, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34988002

RESUMO

PURPOSE: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. MATERIALS AND METHODS: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. RESULTS: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot (P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values (P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. CONCLUSION: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

7.
Int J Comput Dent ; 23(2): 183-189, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32337516

RESUMO

AIM: To describe a method of digitally customizing 3D-printed face mask designs using 3D face scans and free software. MATERIALS AND METHODS: The procedure of creating customized face masks initially involved importing and aligning STL files of face scans and mask components in free CAD software. The imported mask described in this article is composed of three different STL files (body, filter structure, and grid). The body of the mask was then edited to fit precisely into the face scan STL by using the software's offset tool, followed by adjustments and smoothening of the surfaces of the edges. The resulting customized body of the mask plus the filter and grid STL files were exported and 3D printed with polylactic acid (PLA) filament using a fused deposition modeling (FDM) 3D printer. For the purposes of comparison, a conventional 3D-printed mask (from the original STL files, without being customized for the face scan) was also 3D printed from the original STL files. Both face masks were tested on the same two volunteers. RESULTS: The customized 3D-printed face mask presented a higher adaptation compared with the conventional face mask. The area of facial contact matched the one digitally designed in the software. The 3D-printed grid could clip exactly into the filter, which in turn could be precisely screwed into the body of the face mask. CONCLUSION: Within the limitations of this technical report, the present findings suggest that customized 3D-printed face masks with enhanced adaptation can be digitally designed using face scans and free CAD software.


Assuntos
Impressão Tridimensional , Software , Humanos
8.
Braz. j. oral sci ; 19: e200201, jan.-dez. 2020. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1177450

RESUMO

Aim: To perform a scoped literature review on advantages of digital workflows in dentistry that could be widely adopted to address safety issues raised during the coronavirus (COVID-19) pandemic. Methods: Recent studies on any advantages of digital dentistry ­ as compared to conventional methods ­ that could help addressing the new safety demands for dental treatments that emerged due to the current pandemic were included. PUBMED, Embase, and Web of Knowledge databases were searched for eligible articles published in the last five years. The guidelines of PRISMA statement were followed during data extraction and evaluation. Results: The present search strategy yielded 181 publications. After application of exclusion criteria, a total of 34 studies were finally considered eligible to be discussed. Among the most important advantages of digital dentistry that contribute to safety during the current pandemic are: reduced number of clinical appointments required, shorter chairside time, less invasive surgeries and safer procedures. Conclusion: Within the limitations of this study, the findings observed herein suggest that the use of digital workflows in dentistry could lead to increased safety and reduced transmission of COVID-19 during the current pandemic


Assuntos
Tecnologia Odontológica , Infecções por Coronavirus , Odontologia , Fluxo de Trabalho
9.
Imaging Sci Dent ; 44(2): 171-5, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24944969

RESUMO

One of the most common oral surgical procedures is the extraction of the lower third molar (LTM). Postoperative complications such as paresthesia due to inferior alveolar nerve (IAN) injury are commonly observed in cases of horizontal and vertical impaction. The present report discusses a case of a vertically impacted LTM associated with a dentigerous cyst. An intimate contact between the LTM roots and the mandibular canal was observed on a panoramic radiograph and confirmed with cone-beam computed tomographic (CBCT) cross-sectional cuts. An orthodontic miniscrew was then used to extrude the LTM prior to its surgical removal in order to avoid the risk of inferior alveolar nerve injury. CBCT imaging follow-up confirmed the success of the LTM orthodontic extrusion.

10.
J Prosthodont ; 23(4): 328-32, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24118202

RESUMO

The present retrospective case series is aimed at evaluating a staged approach using a removable partial denture (RPD) as an interim prosthesis in treatment to correct a failing dentition until such time as a full-arch fixed implant-supported prosthesis may be inserted. Eight patients, who had undergone maxillary full-arch rehabilitation with dental implants due to poor prognosis of their dentitions, were analyzed. All treatment included initial periodontal therapy and a strategic order of extraction of hopeless teeth. An RPD supported by selected teeth rehabilitated the compromised arch during implant osseointegration. These remaining teeth were extracted prior to definitive prosthesis delivery. Advantages and drawbacks of this technique were also recorded for the cases presented. Among the advantages provided by the staged approach are simplicity of fabrication, low cost, and ease of insertion. Additionally, RPD tooth support prevented contact between the interim prosthesis and healing abutments, promoting implant osseointegration. The main drawbacks were interference with speech and limited esthetic results. Implant survival rate was 100% within a follow-up of at least 1 year. The use of RPDs as interim prostheses allowed for the accomplishment of the analyzed rehabilitation treatments. It is a simple treatment alternative for patients with a low smile line.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Prótese Parcial Temporária , Reabilitação Bucal/métodos , Idoso , Dente Suporte , Implantação Dentária Endóssea/métodos , Implantes Dentários , Prótese Parcial Imediata , Prótese Parcial Removível , Estética Dentária , Feminino , Seguimentos , Humanos , Masculino , Maxila/cirurgia , Pessoa de Meia-Idade , Osseointegração/fisiologia , Planejamento de Assistência ao Paciente , Estudos Retrospectivos , Fala/fisiologia , Cirurgia Assistida por Computador/métodos , Extração Dentária/métodos , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA